Stamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544f

Product Details
Customization: Available
Conditions
of Use:
Car Type, Trailer Type, Marine, Land Use
Usage: Emergency Crew, Standby Unit, Common Units
Manufacturer/Factory, Group Corporation
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Stamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544f
  • Stamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544f
  • Stamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544f
  • Stamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544f
  • Stamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544f
  • Stamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544f
Find Similar Products

Basic Info.

Model NO.
WT-HCI544
Output Type
AC Three Phase
Cooling
Method
Water Cooling
Installation
Method
Fixed
Generator
Type
Diesel Generator
Output
400/230V 380/220V 440/220V 415/240V 480/277V
Phase
Single or Three Phase
Frequency
50Hz/60Hz
Engine Speed
1500rpm/1800rpm
IP
23
Cooling System
Water Cooled
Voltage Regulaor
AVR Auto Voltage Regulator
Alternator
Brushless, Self Exciting, 100% Copper
Insulation Class
Class "H"
Quality Standard
ISO9001, ISO14001, CE
Transport Package
Plastic Seaworth Packing with Carton
Specification
500x800x1050MM
Trademark
Stamfor
Origin
China
HS Code
8501310000
Production Capacity
8000

Product Description

Stamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544fStamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544f 
WT SERIES STAMFROD SIMILAR AC ALTERNATOR SPECIFICATION
AC Brushless atlernator,3Ph, 0.8PF, IP23, H insulation.
MODEL 3Phase/50Hz/340-415V   3Phase/60Hz/220-440V-480V
Standby Power Continuous power   Standby Power Continuous power
KVA KW KVA KW   KVA KW KVA KW
WT184E 22 18 20 16   25  21  23  18 
WT184F 30 24 27 22   34  28  31  25 
WT184J 44 35 40 32   51  40  46  37 
WT224D 55 44 50 40   63  51  57  46 
WT224E 70 56 63 50   80  64  72  57 
WT224F 88 70 80 64   101  80  92  74 
WT274C 110 88 100 80   126  101  115  92 
WT274D 125 100 113 90   144  115  130  103 
WT274E 150 120 137.5 110   172  138  158  126 
WT274F 165 132 150 120   190  152  172  138 
WT274G 200 160 180 144   230  184  207  166 
WT274H 220 176 200 160   253  202  230  184 
WT274J 250 200 230 184   287  230  264  211 
WT274K 275 220 250 200   316  253  287  230 
WT444D 300 240 275 220   345  276  316  253 
WT444E 350 280 313 250   402  322  360  287 
WT444F 413 330 375 300   475  379  431  345 
WT544C 500 400 450 360   575  460  517  414 
WT544D 550 440 500 400   632  506  575  460 
WT544E 650 520 575 460   747  598  661  529 
WT544F 715 570 650 520   822  655  747  598 
WT544G 825 660 750 600   948  759  862  690 
WT634C 880 704 800 640   1011  809  920  736 
WT634D 1000 800 910 728   1149  920  1046  837 
WT634E 1100 880 1000 800   1264  1011  1149  920 
WT634F 1250 1000 1100 900   1437  1149  1264  1034 
WT634G 1375 1100 1250 1000   1580  1264  1437  1149 
WT634H 1512 1210 1375 1100   1738  1391  1580  1264 
WT634J 1650 1320 1500 1200   1897  1517  1724  1379 
WT734C 1875 1500 1700 1360   2155  1724  1954  1563 
WT734D 2063 1650 1875 1500   2371  1897  2155  1724 
WT734E 2250 1800 2000 1600   2586  2069  2299  1839 
WT734H 2500 2000 2250 1800   2874  2299  2586  2069 
SPECIFICATIONS & OPTIONS        
STANDARDS        
WINTPOWER industrial generators meet the
requirements of BS EN 60034 and the relevant section
of other international standards such as BS5000, VDE
0530, NEMA MG1-32, IEC34, C22.2-100, AS1359.
Other standards and certifications can be considered on
request.
AUTO VOLTAGE REGULATORS        
SX460 AVR - STANDARD        
With this self excited control system the main stator
supplies power via the Automatic Voltage Regulator
(AVR) to the exciter stator. The high efficiency
semiconductors of the AVR ensure positive build-up
from initial low levels of residual voltage.
The exciter rotor output is fed to the main rotor through a
three phase full wave bridge rectifier. This rectifier is
protected by a surge suppressor against surges caused,
for example, by short circuit.
AS440 AVR        
With this self-excited system the main stator provides
power via the AVR to the exciter stator. The high
efficiency semi-conductors of the AVR ensure positive
build-up from initial low levels of residual voltage.
The exciter rotor output is fed to the main rotor through a
three-phase full-wave bridge rectifier. The rectifier is
protected by a surge suppressor against surges caused,
for example, by short circuit or out-of-phase paralleling.
The AS440 will support a range of electronic
accessories, including a 'droop' Current Transformer
(CT) to permit parallel operation with other ac
generators.
MX341 AVR        
This sophisticated AVR is incorporated into the WINTPOWER
Permanent Magnet Generator (PMG) control system.
The PMG provides power via the AVR to the main
exciter, giving a source of constant excitation power
independent of generator output. The main exciter
output is then fed to the main rotor, through a full wave
bridge, protected by a surge suppressor. The AVR has
in-built protection against sustained over-excitation,
caused by internal or external faults. This de-excites the
machine after a minimum of 5 seconds.
An engine relief load acceptance feature can enable full
load to be applied to the generator in a single step.
If three-phase sensing is required with the PMG system
the MX321 AVR must be used.
We recommend three-phase sensing for applications
with greatly unbalanced or highly non-linear loads.
MX321 AVR        
The most sophisticated of all our AVRs combines all the
features of the MX341 with, additionally, three-phase
rms sensing, for improved regulation and performance.
Over voltage protection is built-in and short circuit
current level adjustments is an optional facility.
WINDINGS & ELECTRICAL PERFORMANCE        
All generator stators are wound to 2/3 pitch. This
eliminates triplen (3rd, 9th, 15th …) harmonics on the
voltage waveform and is found to be the optimum design
for trouble-free supply of non-linear loads. The 2/3 pitch
design avoids excessive neutral currents sometimes
seen with higher winding pitches, when in parallel with
the mains. A fully connected damper winding reduces
oscillations during paralleling. This winding, with the 2/3
pitch and carefully selected pole and tooth designs,
ensures very low waveform distortion.
TERMINALS & TERMINAL BOX        
Standard generators are 3-phase reconnectable with 12
ends brought out to the terminals, which are mounted on
a cover at the non-drive end of the generator. A sheet
steel terminal box contains the AVR and provides ample
space for the customers' wiring and gland
arrangements. It has removable panels for easy
access.
SHAFT & KEYS        
All generator rotors are dynamically balanced to better
than BS6861:Part 1 Grade 2.5 for minimum vibration in
operation. Two bearing generators are balanced with a
half key.
INSULATION/IMPREGNATION        
The insulation system is class 'H'.
All wound components are impregnated with materials
and processes designed specifically to provide the high
build required for static windings and the high
mechanical strength required for rotating components.
QUALITY ASSURANCE        
Generators are manufactured using production
procedures having a quality assurance level to BS EN
ISO 9001.
The stated voltage regulation may not be maintained in
the presence of certain radio transmitted signals. Any
change in performance will fall within the limits of
Criteria 'B' of EN 61000-6-2:2001. At no time will the
steady-state voltage regulation exceed 2%.
NB Continuous development of our products entitles us
to change specification details without notice, therefore
they must not be regarded as binding.
Front cover drawing typical of product range.
 Stamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544fStamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544fStamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544fStamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544fStamfor AC Alternator Hci444D Hci444es Hci444e Hci444fs Hci444f Hci544c Hci544D Hci544e Hci544fs Hci544f

ΔFAQ
What's your power range of Generators?
Answer:  We can offer the range from 5kva~3000kva.
2.What's your delivery time?
Answer:  Generally,we can delivery in 15-35 days after confirmation of order.
3.What's your payment?
Answer: We can accept T/T 30% in advance, and the balance 70% shall be paid before shipment
or L/C at sight.  But based on some special project and special order,we can do something support on payment item.
4.What's your warranty?
One year or 1000 hours (according to whichever reach first) from Ex-Factory date 
5.What's your MOQ?
Answer:We accept power generator MOQ is 1 set .

WINTPOWER Service System
Customer-focused traditional service better and better service levels worldwide-network Service
Concepts:Ensure that customers at ease using for WINTPOWER Products Serving the customers, WINTPOWER gains trust .Work together with Customers During the service period, WINTPOWER do best firstly and protects customers' interests.
In case of failure to use the generator, WINTPOWER help customer until they know how to use
 

WINTPOWER Service Principles
Customer foremost and honesty as foundation. Serving the customers heart and soul at all levels 24 hours each day.


Δ Factory Inspection: the test items before delivery are mainly as follows:                                                            
1.Each gensets shall be put into commission and loading more than 1 hours totally. They are tested on idle
load, testing range 25% 50% 75% 100% 110% 75% 50% 25% 0%
2.The noise level is tested by requested
3.All of the meters on the control panel shall be tested
The appearance of the genset and all of the label and nameplate shall be checked
 