Part name: Water Heater (Jacket Heater)
Model: HT10M
Technical Parameters
Rated Power 1190W
Rated Voltage AC240V
Rated Current 5A
Engine Displacement(L) 2.5-7
Thermostat Set Point (40±3 )ºC
Thermostat Range Off:(40±3)ºC Reset:(25±6)ºC
Overheating Switch Range Off:(110±3)ºC Reset:Manual≤95ºC
Electrical Strength AC 1.5KV 1min
Insulating Resistance ≥50MΩ
Inlet/Outlet Size 3/4″(Φ19mm)
Max. Water Pressure 0.5MPa
Protection Level IP54
Vibration Resistance (5~8)Hz;Amplitude ±7.5mm;Tri-axia;(8~500)Hz;a=2g;Tri-axia;
Shock Resistance Half-sine;Wave;apeak=50g;Tri-axia;
Overheat manual reset
Manual test
Product Overview
HT Series Water Heater enjoys wide application on various engine coolant preheaters. It has fine cast aluminum enclosure and self-extinguishing engineering plastics end closure, multiple installation ways and easy and convenient use.
If during cranking the outside temperature is lower than 4 ºC, engine coolant and lubricant may condense into solid state and lose their lubricating and cooling properties, which can damage the engine. Engine heater should be installed to ensure normal starting and running of the engine when the outside temperature is lower than 4 ºC.
HT Series Water Heater combines the following features: cast stainless steel inner pipes and end closure with high corrosion resistance; power, heating and overheat protection light indicators; 3 kinds of heaters with different heating temperature are optional (Standard heater: 40 ºC; 50 ºC and 60 ºC heaters are needed to be customized).
This product is suitable for various engine with (0~13.) L displacement.
PERFORMANCE AND CHARACTERISTICS
1. Fine cast aluminum enclosure and special surface treatment with high corrosion resistance and high/low temperature capability;
2. Stainless steel inner pipes and end closure with high corrosion resistance;
3. Coolant temperature is controlled by thermostat which is installed within the heater. It has simple connections and high reliability;
4. power, heating and overheat protection light indicators make it easy to observe the heater status;
5. There is a water drain valve with seal ring on the bottom of the heater so as to be used when needed;
6. Users can press "Test" button to test-run the machine in the extremely high ambient temperature;
7. Overheating thermostat provides the protection of dry heating and overheating;
8. Multiple installation ways apply to different installation situations;
9. This product can work normally at -25 ºC temperature.
ΔFAQ
1.What's your power range of Generators?
Answer: We can offer the range from 5kva~3000kva.
2.What's your delivery time?
Answer: Generally,we can delivery in 15-35 days after confirmation of order.
3.What's your payment?
Answer: We can accept T/T 30% in advance, and the balance 70% shall be paid before shipment
or L/C at sight. But based on some special project and special order,we can do something support on payment item.
4.What's your warranty?
One year or 1000 hours (according to whichever reach first) from Ex-Factory date
5.What's your MOQ?
Answer:We accept power generator MOQ is 1 set .
WINTPOWER Service System
Customer-focused traditional service better and better service levels worldwide-network Service
Concepts:Ensure that customers at ease using for WINTPOWER Products Serving the customers, WINTPOWER gains trust .Work together with Customers During the service period, WINTPOWER do best firstly and protects customers' interests.
In case of failure to use the generator, WINTPOWER help customer until they know how to use
WINTPOWER Service Principles
Customer foremost and honesty as foundation. Serving the customers heart and soul at all levels 24 hours each day.
Δ Factory Inspection: the test items before delivery are mainly as follows:
1.Each gensets shall be put into commission and loading more than 1 hours totally. They are tested on idle
load, testing range 25% 50% 75% 100% 110% 75% 50% 25% 0%
2.The noise level is tested by requested
3.All of the meters on the control panel shall be tested
The appearance of the genset and all of the label and nameplate shall be checked