• Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12
  • Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12
  • Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12
  • Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12
  • Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12
  • Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12

Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12

Conditions
of Use:
Car Type, Trailer Type, Marine, Land Use
Usage: Emergency Crew, Standby Unit, Common Units
Output Type: AC Three Phase
Cooling
Method:
Water Cooling
Installation
Method:
Fixed
Generator
Type:
Diesel Generator
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Group Corporation

Basic Info.

Model NO.
ACD175A-24
Engine Speed
1500rpm/1800rpm
Frequency
50Hz/60Hz
Delivery
by Sea or by Air
Part Type
Brand New
Quality Standard
ISO9001, ISO14001, CE
Transport Package
Carton Packing
Specification
180*180*170mm; 2.7 kgs
Trademark
OEM
Origin
China
HS Code
8503009090
Production Capacity
10000

Product Description

Part name: Electric Actuator
Part number: ACD175A-24

12V/24V ACD175A,  ACD175 Electronic Actuator ACD175A-12V / ACD175A-24V For Generator Engine
Generator Actuator ACD175
· Mounts directly to a P Series Fuel Injection Pump
· Right-hand rack
· Capable of controlling pumps on engines up to 8-cyl.
· Includes manual shut-off mechanism
· Connects directly to the fuel rack bellows
· Compact size, fast response <35msec
· Cost effective design
· Feedback position available
The Engine Actuator ACD175A is designed to mount directly to inline fuel injection pumps, with a right hand rack in place of the mechanical governor. An optional external fuel shut off lever is provided to manually override the actuator's control. Also provided, as standard equipment, is an adjustable internal maximum fuel limit.

The Engine Actuator ACD175A can control fuel pumps up to 8 cylinders. The ACD175A Generator Actuator was designed with two isolated chambers. The upper chamber is wet with oil and contains the connection to the fuel rack and an optional manual shut off mechanism. The sealed lower chamber contains the electromagnetic components.

· Performance of ACD175 Engine Actuator
· Force: 6.2 lbs (27.5N)
· Operating Stroke: 0.80 in (21mm)
· Response Time (10-90% 2-19mm): 35 MSEC
· Internal Sealing Pressure: 2 bar (29 psi)
· Electrical Power Input
· Operating Voltage: 12 VDC, 24 VDC
· Coil Resistance: 12 VDC Version- 1.7+/-0.2 OHMS; 24 VDC Version- 7.2+/-0.5 OHMS
· Nominal Operating Current: 12 VDC Version- 4.0 A; 24 VDC Version- 2.0 A
Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12
Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12

Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12Electric Actuator Acd175A-24 for Diesel Generator OEM Actuator Electronic Actuator Acd175A-12

 ΔFAQ
1.What's your power range of Generators?
Answer:  We can offer the range from 5kva~3000kva.
2.What's your delivery time?
Answer:  Generally,we can delivery in 15-35 days after confirmation of order.
3.What's your payment?
Answer: We can accept T/T 30% in advance, and the balance 70% shall be paid before shipment
or L/C at sight.  But based on some special project and special order,we can do something support on payment item.

4.What's your warranty?
One year or 1000 hours (according to whichever reach first) from Ex-Factory date 
5.What's your MOQ?
Answer:We accept power generator MOQ is 1 set .

WINTPOWER Service System
Customer-focused traditional service better and better service levels worldwide-network Service
Concepts:Ensure that customers at ease using for WINTPOWER Products Serving the customers, WINTPOWER gains trust .Work together with Customers During the service period, WINTPOWER do best firstly and protects customers' interests.
In case of failure to use the generator, WINTPOWER help customer until they know how to use
 

WINTPOWER Service Principles
Customer foremost and honesty as foundation. Serving the customers heart and soul at all levels 24 hours each day.


Δ Factory Inspection: the test items before delivery are mainly as follows:                                                            
1.Each gensets shall be put into commission and loading more than 1 hours totally. They are tested on idle
load, testing range 25% 50% 75% 100% 110% 75% 50% 25% 0%
2.The noise level is tested by requested
3.All of the meters on the control panel shall be tested
The appearance of the genset and all of the label and nameplate shall be checked

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Group Corporation
Plant Area
>2000 square meters
Management System Certification
ISO 9001, ISO 14001, ISO 20000, OHSAS/ OHSMS 18001